Health

Hardware that supports monitoring displays information about hardware status, such as temperature, voltage, current, fan speed, power supply state and power consumption. The same readings are also available in Winbox, on the System → Health tab. Devices without hardware sensors print nothing: this includes CHR and virtual machines, and boards that simply have no sensors (for example the hAP ax²).

Example on the CCR1072-1G-8S+ device:

[admin@MikroTik] > /system/health/print
Columns: NAME, VALUE, TYPE
# NAME VALUE TYPE
0 power-consumption 50.8 W
1 cpu-temperature 43 C
2 fan1-speed 5654 RPM
3 fan2-speed 5825 RPM
4 fan3-speed 5800 RPM
5 fan4-speed 5750 RPM
6 board-temperature1 29 C
7 board-temperature2 28 C
8 psu1-voltage 0 V
9 psu2-voltage 12.1 V
10 psu1-current 0 A
11 psu2-current 4.2 A

The TYPE column shows the unit of the reading: C is degrees Celsius, RPM is fan speed, V is voltage, A is current and W is power consumption. Scripts see the same values as the CLI shows. SNMP uses deci-units for temperature, voltage and power (23.8 V → 238), and current in mA in the legacy OIDs or dA in the dynamic gauge table (see the SNMP section below).

To print a single reading, filter it by name:

[admin@MikroTik] > /system/health/print where name="cpu-temperature"
Columns: NAME, VALUE, TYPE
# NAME VALUE TYPE
0 cpu-temperature 43 C

To see what health data a specific RouterBOARD product supports, check the product specification at mikrotik.com.

Readings​

ReadingUnitDescription
voltageVSupplied voltage on devices with a single power input
psuN-voltageVVoltage of power supply N
psuN-input-voltageVInput (mains) voltage of power supply N
jack-voltage, 2pin-voltage, poe-in-voltageVVoltage of a specific power input (on devices without PSUs)
poe-outN-voltageVVoltage on PoE-out port N
psuN-currentACurrent drawn by power supply N
power-consumptionWTotal power consumption
poe-out-consumptionWCurrent PoE-out power consumption
psuN-powerWPower of power supply N
temperatureCDevice temperature on devices with a single sensor
cpu-temperatureCCPU temperature
board-temperatureNCBoard temperature sensor N
phy-temperatureCPHY temperature
sfp-temperatureCSFP module temperature
switch-temperatureCSwitch chip temperature
pcie-switch-temperatureCPCIe switch temperature
psuN-temperatureCTemperature of power supply N
fan-state—Fan state: ok or fail
fanN-speedRPMSpeed of fan N
psuN-fan-speedRPMSpeed of the internal fan of power supply N
psuN-state—Power supply N state (see the state table below)

Numbered names (psuN, fanN, board-temperatureN, poe-outN) use indexes starting from 1, and the count depends on the device. Which of the readings are present depends on the hardware sensors of the device.

A fan speed reading of 0 RPM when the device has a high temperature can mean the fan has stopped or failed.

Voltage​

Routers that support voltage monitoring display the supplied voltage value. In CLI, Winbox and scripts it is reported in volts; over SNMP it is in dV (the CLI value multiplied by 10).

Routers that have PEXT and PoE power input are calibrated using PEXT. As a result, the value shown over PoE can be lower than input voltage due to additional Ethernet protection chains.

[admin@MikroTik] > /system/health/print
Columns: NAME, VALUE, TYPE
# NAME VALUE TYPE
0 voltage 23.8 V
1 temperature 39 C

Temperature​

Routers that support temperature monitoring display a temperature reading. In CLI, Winbox and scripts it is reported in degrees Celsius; over SNMP the value is multiplied by 10. Different devices use different temperature sensors, for example cpu-temperature, board-temperature1, sfp-temperature, phy-temperature or switch-temperature. Some readings appear only when the corresponding component is present, for example sfp-temperature shows only when an SFP module is installed. You can find the device tested ambient temperature range in the specification description at mikrotik.com. The tested ambient temperature range is the temperature in which the device can be physically located. It is not the same as the temperature reported by the system health monitor.

Power supply states​

Devices with redundant power supplies report the state of each power supply. For battery-backed devices, see the UPS page. Possible values are:

ValueDescription
okThe power supply works normally.
failThe power supply has failed.
not-presentNo power supply is detected in this slot.
idleThe power supply is present but idle.
no-inputThe power supply has no input power.

A value of fail or no-input indicates a problem with the power supply or its power source.

Legacy devices​

If the old revision CRS112, CRS210 and CRS109 devices are powered with PoE - Health will show correct voltage only up to 26.7 V. If higher voltage is used, Health will show a constant 16 V.

x86 (legacy PC hardware) based devices use a different set of reading names, for example core, 3.3v, 5v, 12v, lm87-temp, cpu-temp, board-temp, voltageN, tempN and fanN.

Fan control and behavior​

The /system/health/settings menu controls fan behavior on devices with fans.

Three parameters can start the fans: PoE-out consumption, SFP temperature and CPU temperature. When one of the parameters exceeds the optimal value, the fans start.

PoE-out consumption​

If a device has PoE-out, then the fan RPM will change as described below:

PoE-out loadRPM % of max fan speed
0%..24%Fan speed 0%
25%..46%Fan speed 25%
47%..70%Fan speed 50%
71%..92%Fan speed 75%
93%..Fan speed 100%

For devices with PWM fans, the speed will linearly increase or decrease from 9..88% (below 100 W the fan RPM is 0).

Manual fan-control option​

Manual fan-control is available for CRS3xx, CRS5xx and CCR2xxx devices, and for the revised CCR1036-8G-2S+-r2, CCR1036-12G-4S-r2 and CCR1016-12S-1S+-r2 devices.

Set them in /system/health/settings — every parameter, including the manual fan-control options fan-mode, use-fan, use-fan2, fan-switch and fan-on-threshold, and the read-only active-fan/active-fan2 states, is described in the CLI reference. Devices with main and auxiliary fans, such as RB1100, CCR1016 and CCR1036 devices, also support manual fan-control.

For example, to keep the fans running at least at a quarter of their maximum speed:

/system/health/settings/set fan-min-speed-percent=25

When the main fan fails, the device automatically switches to the auxiliary fan and active-fan (or active-fan2) changes to auxiliary. Fan state changes are also written to the log on CRS3xx, CRS5xx, CCR2xxx, CCR1016r2 and CCR1036r2 devices.

Use the /system/health/settings/detect-fans command to detect the fans connected to the device, for example after installing or replacing a fan.

Fan control in detail​

If at least one of the internal measured temperatures (CPU, SFP, switch, board) exceeds fan-target-temp, the fans start spinning. The higher the temperature, the faster the fans spin.

  • Devices with PWM fans: the fans increase their RPM linearly to keep the temperature at fan-target-temp if possible, and reach their maximum RPM when the temperature equals or exceeds fan-full-speed-temp.
  • Devices with DC fans: the fans start spinning at a higher minimum RPM by default. This may cool the device so much that the fans turn off completely if fan-min-speed-percent is 0%; with the default 12% the fans never stop fully, which reduces the noise and on/off peaks. When the temperature rises back to fan-target-temp, the fans turn on again.

One exception: S+RJ10 modules have a temperature threshold of 65 C before they trigger the fans, so the fans start spinning at a higher initial speed to cool the device. All the previously mentioned functionality is directly related to the fan-control-interval parameter value, as it determines how often the fan controller monitors all sensor data and applies fan-control changes.

PWM and DC fans react to fan-control differently. PWM fans increase or decrease their RPM in a linear way. However, DC fans have only a few possible speed ratings at which they can operate.

All readings are approximate. Their purpose is to inform users about possible or upcoming failures.

Monitor health and get alerts​

SNMP trap​

For SNMP-based monitoring, enable the temp-exception trap generator. The router then sends an SNMP trap when the temperature reaches 100 C or the value set with cpu-overtemp-threshold. See the SNMP page for details.

SNMP OIDs​

All health readings are exposed in the MIKROTIK-MIB under the 1.3.6.1.4.1.14988.1.1.3 sub-tree, in the form .1.3.6.1.4.1.14988.1.1.3.<index>.0:

IndexObject nameReading
1mtxrHlCoreVoltageCore voltage (V)
2mtxrHlThreeDotThreeVoltage3.3 V rail voltage
3mtxrHlFiveVoltage5 V rail voltage
4mtxrHlTwelveVoltage12 V rail voltage
5mtxrHlSensorTemperatureTemperature at the sensor chip (C)
6mtxrHlCpuTemperatureCPU temperature
7mtxrHlBoardTemperatureBoard temperature
8mtxrHlVoltageMain voltage
9mtxrHlActiveFanName of the active fan
10mtxrHlTemperatureTemperature
11mtxrHlProcessorTemperatureProcessor temperature
12mtxrHlPowerPower consumption (W)
13mtxrHlCurrentCurrent (mA)
14mtxrHlProcessorFrequencyCPU frequency (MHz)
15mtxrHlPowerSupplyStatePSU state (0 = not ok, 1 = ok)
16mtxrHlBackupPowerSupplyStateBackup PSU state (0 = not ok, 1 = ok)
17mtxrHlFanSpeed1Fan 1 speed (RPM)
18mtxrHlFanSpeed2Fan 2 speed (RPM)
19mtxrAlarmSocketStatusAlarm socket status (0 = inactive, 1 = active)

Temperature, voltage and power values are multiplied by 10 (divide by 10 to get the value). Current is reported in mA, frequency in MHz and fan speeds in RPM. Which indexes return a value depends on the hardware sensors of the device; run /system/health/print oid on a device to see its actual OID mapping.

The static OIDs in the table are the fixed legacy set. Newer readings — such as fan speeds beyond fan 2, the per-power-supply readings (psuN-*), pcie-switch-temperature, and PoE-out voltages — are available in a dynamic gauge table at .1.3.6.1.4.1.14988.1.1.3.100. Each row of this table lists a reading by name (mtxrGaugeName), together with its raw value (mtxrGaugeValue) and unit (mtxrGaugeUnit: celsius(1), rpm(2), dV(3), dA(4), dW(5) or status(6)). The dV, dA and dW units are deci-volts, deci-amperes and deci-watts, so divide the raw value by 10.

REST API​

With the REST API you can read the same readings as JSON:

curl -k -u admin https://192.168.88.1/rest/system/health

See the REST API page for details.

Send an email alert​

With a script you can check the readings periodically by using the scheduler and send an email when a limit is exceeded. First configure the E-mail settings, then add the script and a scheduler entry:

/system/script/add name=temp-alert source={
:local t [/system/health/get [find name="cpu-temperature"] value]
:if ($t > 65) do={/tool/e-mail/send to="admin@example.com"
subject="Router overheating" body=("CPU temperature: " . $t)}
}
/system/scheduler/add name=temp-alert start-time=startup interval=5m on-event=temp-alert

In scripts the values are plain numbers as printed by the CLI (54 for 54 C), so the example compares against 65.

For all parameters, see the /system/health and /system/health/settings CLI reference pages.