sync-e
system/sync-e
Syscap: synce
Type: Settings Directory
| Argument | Type | Description |
|---|---|---|
| enabled | bool | enable or disable SyncE |
| wait-to-restore | time | time to wait before using a reference after it becomes valid again |
| hold-off | time | time to wait before switching away from the current reference after it becomes invalid |
| quality-level | enum (dnu | eprtc | eprc | prtc | prc | ssu-a | ssu-b | eec1 | prs | stu | st2 | tnc | st3e | eec2 | eeec | prov) { dnu:0, eprtc:5, eprc:15, prtc:6, prc:4, ssu-a:3, ssu-b:2, eec1:12, prs:7, stu:8, st2:9, tnc:10, st3e:11, eec2:13, eeec:16, prov:14 } | minimum accepted ESMC quality level; lower-quality references are not selected |
| network | enum (option-1 | option-2) { option-1:0, option-2:1 } | ESMC network option used when interpreting quality levels |
| holdover | time | time to keep the last reference active when no valid reference is available before entering local holdover |
| esmc-timeout | time | time without a valid ESMC message before the reference is considered lost |
| essm | bool | use eSSM quality-level information in transmitted and received ESMC frames |