Skip to main content
Version: 7.26

monitor


system/ptp/monitor​

Conditions: !smips
Syscap: ptp
Type: Command
Show the detailed status and synchronization accuracy of a PTP profile instance, monitor <number or name>.

Read-only ArgumentTypeDescription
namestringName of the PTP profile instance
clock-idstringIdentifier of the local clock
priority1numThe local priority1 value in the grandmaster election
priority2numThe local priority2 value in the grandmaster election
i-am-gmboolWhether this device is the grandmaster clock
gm-clock-idstringIdentifier of the grandmaster clock
gm-priority1numThe priority1 of the grandmaster clock
gm-priority2numThe priority2 of the grandmaster clock
master-clock-idstringIdentifier of the master clock in the PTP path (the grandmaster clock or a boundary clock)
slave-portiface_enumThe local port connected towards the master clock
freq-driftnumFrequency drift between the master and the slave clock, in parts per billion
offsetnumTime difference between the master and the slave clock, in nanoseconds
slave-port-delaynumMeasured delay for packets between the two clocks, in nanoseconds (cable and transceiver lengths matter)