Documentation updates - October 6, 2026
Summary of documentation changes made on October 6, 2026.
Management Tools
- CMR: The Alert rules section now separates state alerts from event alerts, with a table that compares them:
- A state alert (CPU, memory, disk, and health thresholds,
connected,disconnected-more-than,upgrade-available) stays active while all its conditions match. It runs its actions once when it becomes active and counts indevices-onand the dashboard until it clears. - An event alert (
interface-change,upgrade-done,upgrade-job-done,rebooted,unpaired-device-connected, or a log message matched bylog-topicsandlog-regex) runs its actions for every occurrence and never stays active. A rule can combine several state conditions but has at most one event condition. - A new Device and system scope section: most alerts apply per device, and
upgrade-job-doneis a system alert that reports a whole upgrade job without device context. show-deviceslists the devices on which a rule's state alert is active. It lists no devices for an event alert, whosefiredvalue counts the occurrences instead.
- A state alert (CPU, memory, disk, and health thresholds,
- CMR, CMR-Client: Corrections to connecting and pairing clients:
- Clients connect to the server over TCP port
54321. Allow it in the server'sinputchain and in any firewall between the clients and the server. The client troubleshooting forstatus: searchingnow points to the port and the firewalls. - The client's
pairing-requirementsupportsnoneandpassword.confirmexists only on the server, where/cmr/device/pairapproves the pairing. The client-sideconfirmcase is gone from the troubleshooting list. - The client is not supported on the mipsel, smips, and powerpc architectures. The pages named only smips and powerpc.
- Clients connect to the server over TCP port
CLI Reference
/cmr/alert,show-devices: Descriptions follow the state and event split.connectedis a state condition,rebootedand the log conditions are event conditions,devices-oncounts only active state alerts, andreset-on-disconnectapplies to state alerts.show-deviceslists the devices on which the rule's state alert is active.
Hardware
- CRS310-8G+2S+IN: The reset button section lists its three functions. A configuration reset now waits for the PWR LED to flash instead of the USR LED, and Netinstall describes both the Regular Booter (press Reset 1–2 seconds after power-on) and the Backup Booter (hold Reset while powering on until the LED blinks, turns steady, and goes off).